USER SYMPTOM: Display shows Fill System or System Filling; pump runs but little/no water dispenses; brewing stops or loops on filling.
ROOT CAUSE: Water circuit cannot establish stable flow/pressure due to scale restriction, air ingress, or a leaking/stuck membrane pressure regulator at the pump outlet; the machine detects insufficient flow and posts Fill System/System Filling.
REQUIRED TOOLS: Jura descaling tablets; Clean water; Torx T15 driver; Phillips screwdriver; Needle-nose pliers; Replacement membrane pressure regulator (59504/71768 compatible)
Replace filters on schedule, descale when prompted, and avoid letting the tank run dry to reduce air ingestion and pump stress.
Severe mechanical failures sometimes warrant a full machine replacement rather than piecemeal restoration.